Amana fault codes
53 codes from Amana plates on FieldBench. Same number on another maker is a different code.
The list stays open.
- Lockout
1 flash
Retry lockout
Ignition retries exceeded.
1 plate
- Lockout
2 flash
PS closed, inducer off
Single switch welded or IFC input shorted.
1 plate
- Lockout
3 flash
PS open, inducer on
Draft / trap / hose / inducer.
1 plate
- Protect
4 flash
Open limit
Airflow or overfire.
1 plate
- Hazard
5 flash
Flame with valve off
Leaking valve or false flame sense.
1 plate
- Hazard
6 flash
Rollout open
Flame containment.
1 plate
- Protect
7 flash
Low flame
Weak µA.
1 plate
- Lockout
8 flash
Igniter fault
Open / cracked HSI.
1 plate
- Lockout
9 flash
Polarity / ground
L1/N or chassis ground.
1 plate
- Lockout
b0
ECM blower not running
IFC commanded the serial ECM and does not detect it running.
6 plates
- Lockout
b1
ECM communications lost
IFC cannot communicate with the variable-speed blower. Furnace will not operate.
6 plates
- Lockout
b2
Motor HP mismatch vs shared-data set
Connected motor horsepower does not match the value in the furnace shared-data set. Furnace will not operate.
4 plates
- Protect
b2 / b3 / b9
Motor HP / limiting / low CFM
b2 = motor HP does not match the shared-data set. b3 = motor folding back on power/speed/temp. b9 = airflow below calculated minimum.
2 plates
- Protect
b3
Motor limiting (power / speed / temp)
ECM is folding back on power, speed, or temperature. Furnace keeps running at reduced CFM.
2 plates
- Protect
b3 / b9
Motor limiting / low indoor airflow
b3 = folding back on power/speed/temp (reduced CFM). b9 = airflow below calculated minimum.
2 plates
- Lockout
b4 / b5
Motor trip / locked rotor
b4 = lost rotor or overload trip. b5 = locked rotor after 10 start attempts.
1 plate
- Lockout
b4 / b5 / b7
Motor trip / locked rotor / failed start
b4 = lost rotor or overload trip (shuts down and retries). b5 = locked rotor after 10 start attempts. b7 = motor parameters missing or failed to start after 40 attempts.
3 plates
- Protect
b9
Low indoor airflow
Indoor airflow fell below the calculated minimum. Furnace stages down (high to low) and will halt if CFM reaches 0.
2 plates
- Lockout
Comm
Indoor/outdoor data
ComfortBridge data pair only. Invalid as a diagnosis on a 24V Y1/Y2 hookup.
3 plates
- Lockout
Comm / data pair
ComfortBridge bus to stat or outdoor
Indoor lost the communicating thermostat or the outdoor on the data pair. Not a furnace E-code. Not 24V Y.
1 plate
- Lockout
d0 / d4
Shared data / memory card
d0 = IFC has no shared-data set (replacement board, missing card) and cannot drive the serial ECM or calculate CFM. d4 = card rejected (wrong model card).
6 plates
- Lockout
E0
System / ignition lockout
Too many failed ignition attempts or flame losses on this call.
9 plates
- Lockout
E1
Low-stage PS stuck closed
Low-stage pressure switch is made with the inducer off.
7 plates
- Lockout
E2
Low-stage PS stuck open
Inducer is on low and the low-fire switch will not close.
9 plates
- Protect
E3
Open primary / aux / rollout limit
Primary limit opened. Airflow or overfire — not a charge problem.
9 plates
- Hazard
E4
Flame sensed with no call for heat
Rod sees flame with both solenoids de-energized.
9 plates
- Protect
E5
Open 24V fuse
3 A (typical) automotive fuse on the IFC is open.
9 plates
- Protect
E6
Low flame-sense µA
Flame is present but the micro-amp signal is below the IFC threshold.
9 plates
- Lockout
E7
Igniter open / no-ground
IFC did not see the igniter circuit behave as commanded.
9 plates
- Lockout
E8
High-stage PS stuck closed
High-stage pressure switch is made with the inducer not on high.
5 plates
- Lockout
E9
High-stage PS stuck open
Inducer on high, high-stage switch never closes. Classic ‘runs on low, will not go high.’
7 plates
- Lockout
EA
Reversed polarity / poor ground
L1/N reversed or chassis ground missing. Furnace will not operate.
9 plates
- Lockout
Eb / Ec
Gas valve circuit
Internal (Eb) or external (Ec) gas-valve electrical fault.
4 plates
- Hazard
Ed
Open rollout
Manual-reset rollout opened. Treat as flame outside the exchanger until proven otherwise. Door chart may render this as a distinctive 7-seg character — confirm on the unit sticker.
4 plates
- Lockout
EE
No 115V to control / internal / door switch
No line voltage reaching the IFC, door switch open, or an internal control condition. This is power, not a ComfortBridge data-pair code.
6 plates
- Lockout
EEH
Grounding error
IFC failed its ground check (sister to EA).
4 plates
- Lockout
EEJ
Twin error
Twinning miswire or twin terminal active on a standalone unit.
2 plates
- Protect
Electric heat limit / sequencer
Strip overtemp or sequencer failed
A heat-kit limit opened or a sequencer did not bring a bank on. There is no gas-furnace E3 on this machine — this is strip overtemp or a failed sequencer/relay.
1 plate
- Lockout
En
Igniter open
Igniter circuit measures open.
4 plates
- Hazard
FE3 / LE4 / SE5 / rE6
A2L mitigation
Leak / comm / relay alarm from the A2L board when paired with R-32 or R-454B outdoor.
4 plates
- Lockout
HPS
High pressure
Outdoor airflow, overcharge, or restriction opened the high-pressure switch.
4 plates
- Lockout
HPS / LPS
Pressure protection
Still real on an inverter.
1 plate
- Lockout
Hum / no start
Cap / start
Compressor hums, outdoor fan may run.
2 plates
- Status
idle / CF / 1AC / 2AC / Htr
Status, not a fault
idle = standby. CF = continuous fan. 1AC / 2AC = cooling stage. Htr = electric heat staged. These are run states.
1 plate
- Status
idle / Ht / CF
Status, not a fault
Normal run states. idle = standby. Ht = heat running (capacity is a percent, not Ht1/Ht2 stages). CF = continuous fan.
2 plates
- Status
idle / Ht1 / Ht2 / CF / CL1 / CL2
Status, not a fault
Normal run states on the triple display. idle = standby. Ht1 / Ht2 = low / high heat. CF = continuous fan. CL1 / CL2 = cooling stage.
3 plates
- Lockout
Inverter
Drive overcurrent / overheat
L5/L4-class faults on the drive.
1 plate
- Lockout
LE1
Low circulator current
9-speed ECM current too low.
1 plate
- Lockout
LE1 / UE2
Circulator current
ECM current too low (LE1) or unexpected (UE2).
3 plates
- Lockout
LPS
Low pressure / freeze
Suction dropped out — charge, indoor airflow, or TXV.
2 plates
- Lockout
LPS / freeze
Low pressure
Charge, indoor airflow, metering.
2 plates
- Protect
No Y
Outdoor silent
No 24 VAC at the contactor or the coil is open.
2 plates
- Lockout
TWIN
Twin error
Twinning miswire or twin terminal active on a standalone unit. Door card lists TWIN on 0140F20001-B.
1 plate