Amana
2 flash
LockoutPS closed, inducer off
Single switch welded or IFC input shorted.
Walk 2 flash in Diagnose
Sign in for the next measurement
First check
1 Unplug the switch with the inducer off
On Amana AM9S96 this code is the switch made when the inducer is not running. Unplug that switch only. Unplug the only PS. Code change = switch or water in the hose.
Expect: Code changes when the harness is open.
If fail: Wrong switch, or the IFC input is shorted.
If pass: Switch/hose path. Go to step 2.
The rest of the walkthrough is Diagnose.
On the plates
- Unplug the only PS. Code change = switch or water in the hose.
- Hose routed downhill? Residual draft fakes closed.
- IFC input shorted — only after the switch ohms open.
Plates that use 2 flash
Same number, other makers
2 flash on Amana is not the same code on these plates.