Amana codes

Amana

EEJ

Lockout

Twin error

Twinning miswire or twin terminal active on a standalone unit.

Walk EEJ in Diagnose

2 plates — walk the one on the cabinet

First check

1 Is this cabinet actually twinned?

On a standalone Amana AR9T80, nothing belongs on the TWIN terminal. A leftover jumper throws this. If not twinned, nothing should be on the TWIN terminal.

Expect: TWIN empty on a single cabinet.

The rest of the walkthrough is Diagnose.

On the plates

  • If not twinned, nothing should be on the TWIN terminal.
  • Twinned pair must be same family / same IFC revision.

Plates that use EEJ

Same number, other makers

EEJ on Amana is not the same code on these plates.