Amana codes

Amana

6 flash

Hazard

Rollout open

Flame containment.

Walk 6 flash in Diagnose

Sign in for the next measurement

First check

1 Treat this as flame outside the exchanger

Do not reset the Amana AM9S96 rollout and walk away. Write the code, kill the call, and look for flame at the burners, crossover, and vestibule before you do anything else.

Expect: No flame outside the exchanger. Burners seated. Crossover lit.

If pass: Still inspect secondary / flue / condensate before you reset.

The rest of the walkthrough is Diagnose.

On the plates

  • Exchanger, burners, flue.
  • Blocked secondary / condensate.
  • Reset only after the cause is fixed. Recurring rollout is a CO / fire call.

Plates that use 6 flash

Same number, other makers

6 flash on Amana is not the same code on these plates.