Lennox codes

Lennox

6 flash

Lockout

PS lockout

Hardened 3-flash / 2-flash. Retries used up on draft.

Walk 6 flash in Diagnose

3 plates — walk the one on the cabinet

First check

1 Prove inducer and the live code

Do not pull power — that clears the Lennox ML180 active code. Write 6 flash. Is the inducer spinning on this call? Silent inducer is not a pressure switch. Fix chimney / inducer / common vent, then reset.

Expect: 120 VAC at the inducer on a heat call. Wheel turning.

If fail: 120 VAC missing → IFC / door switch / incoming power. Voltage + dead motor → inducer.

If pass: Inducer running + this code → trap, hose, switch, vent (step 2).

The rest of the walkthrough is Diagnose.

On the plates

  • Fix the 3-flash physics (trap/PVC) before you reset.
  • Fix chimney / inducer / common vent, then reset.

Plates that use 6 flash

Same number, other makers

6 flash on Lennox is not the same code on these plates.