Amana
LE1 / UE2
LockoutCirculator current
ECM current too low (LE1) or unexpected (UE2).
Walk LE1 / UE2 in Diagnose
3 plates — walk the one on the cabinet
First check
1 Is the wheel free?
Spin the Amana AR9S96 blower by hand. Ice, debris, or a seized bearing is not a control problem. Confirm the motor type on this plate — serial ECM, 9-speed tap, or X-13 — before you grab a capacitor. Harness seated at motor and IFC. 9-speed ECM is tap-driven — a half-seated plug throws these.
Expect: Wheel free. Correct motor family for this IFC.
The rest of the walkthrough is Diagnose.
On the plates
- Harness seated at motor and IFC. 9-speed ECM is tap-driven — a half-seated plug throws these.
- Locked rotor, wet winding, or wrong motor for the cabinet.
- Do not put a PSC motor on this IFC.
- Do not put a PSC motor or a ComfortBridge serial ECM on this IFC.
- This is Category I metal vent. There is no 96% collector or PVC trap to prime.
- Cap, liner, common-vent tables, inducer wheel, hose on the inducer housing.
Plates that use LE1 / UE2
Same number, other makers
LE1 / UE2 on Amana is not the same code on these plates.