Amana codes

Amana

EEH

Lockout

Grounding error

IFC failed its ground check (sister to EA).

Walk EEH in Diagnose

4 plates — walk the one on the cabinet

First check

1 Hot and neutral at the IFC, not the disconnect

On Amana AR9S80 polarity/ground is measured at the board. A correctly landed disconnect with a swapped whip at the IFC still throws this. Green ground to cabinet and IFC. Painted screw, missing star washer.

Expect: L1 hot, N neutral, ~120 VAC L1 to N, ~0 VAC N to ground.

The rest of the walkthrough is Diagnose.

On the plates

  • Green ground to cabinet and IFC.
  • Painted screw, missing star washer.
  • Green ground to cabinet and IFC. Painted screw, missing star washer.

Plates that use EEH

Same number, other makers

EEH on Amana is not the same code on these plates.