Amana codes

Amana

E6

Protect

Low flame-sense µA

Flame is present but the micro-amp signal is below the IFC threshold.

Walk E6 in Diagnose

9 plates — walk the one on the cabinet

First check

1 Measure µA while it is running

Do not clean first and guess. Series-µA the rod on Amana AMVC96 during a call. Falling µA is oxide, ground, or a dying flame. A hard drop is often the pressure switch or limit opening, not the rod. Clean rod with a non-scratch pad — not sandpaper.

Expect: Flame rod: µA per this IFC sticker, not the AR9T96 card. Rising while running is the goal.

The rest of the walkthrough is Diagnose.

On the plates

  • Clean rod with a non-scratch pad — not sandpaper.
  • Chassis ground to burner box and IFC.
  • Manifold pressure / orifice / LP conversion.
  • Manifold pressure / orifice / LP conversion (this plate uses LPM-33, not LPM-34).
  • Clean rod with a non-scratch pad.
  • Chassis ground, manifold, LP conversion (this plate uses LPM-31 with an LP switch — not LPM-33).
  • Manifold / orifice / LP conversion (this plate is LPM-34 on every SKU).
  • Clean rod, chassis ground.

Plates that use E6

Same number, other makers

E6 on Amana is not the same code on these plates.