Daikin
E6
ProtectLow flame signal
Flame present, µA below the IFC threshold.
Walk E6 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Measure µA while it is running
Do not clean first and guess. Series-µA the rod on Daikin DM80VC during a call. Falling µA is oxide, ground, or a dying flame. A hard drop is often the pressure switch or limit opening, not the rod. Clean rod, chassis ground, manifold / LP conversion.
Expect: Flame rod: µA per this IFC sticker, not the AR9T96 card.
The rest of the walkthrough is Diagnose.
On the plates
- Clean rod, chassis ground, manifold / LP conversion.
- µA per this door card, not the AR9T96 sticker.
- Rod, ground, manifold at the percent it is running — not a single two-stage high-fire number.
Plates that use E6
Same number, other makers
E6 on Daikin is not the same code on these plates.