Amana
E0
LockoutSystem / ignition lockout
Too many failed ignition attempts or flame losses on this call.
Walk E0 in Diagnose
9 plates — walk the one on the cabinet
First check
1 Watch one full try — do not reset
Write the Amana AMVC96 code. Watch inducer, HSI glow, valve click, flame, µA. The step that dies is the repair. Resetting only burns another try into a harder lockout. Watch one full try: inducer, HSI glow, valve click, flame, µA.
Expect: Call → Prove limits → Low inducer / LPS → HSI / low-fire valve → Blower → High fire → Satisfied
The rest of the walkthrough is Diagnose.
On the plates
- Watch one full try: inducer, HSI glow, valve click, flame, µA.
- Gas supply and manifold (low then high).
- Ground and flame-rod cleanliness.
- Do not keep resetting — find which step dies.
- Gas supply and manifold vs this plate (single-stage — no low/high pair).
- Gas supply and manifold vs this 80% plate.
- Do not sit on hourly resets — find which step dies.
- Watch one full try: inducer ramp, HSI, valve, flame, µA.
Plates that use E0
Same number, other makers
E0 on Amana is not the same code on these plates.