Amana codes

Amana

E0

Lockout

System / ignition lockout

Too many failed ignition attempts or flame losses on this call.

Walk E0 in Diagnose

9 plates — walk the one on the cabinet

First check

1 Watch one full try — do not reset

Write the Amana AMVC96 code. Watch inducer, HSI glow, valve click, flame, µA. The step that dies is the repair. Resetting only burns another try into a harder lockout. Watch one full try: inducer, HSI glow, valve click, flame, µA.

Expect: Call → Prove limits → Low inducer / LPS → HSI / low-fire valve → Blower → High fire → Satisfied

The rest of the walkthrough is Diagnose.

On the plates

  • Watch one full try: inducer, HSI glow, valve click, flame, µA.
  • Gas supply and manifold (low then high).
  • Ground and flame-rod cleanliness.
  • Do not keep resetting — find which step dies.
  • Gas supply and manifold vs this plate (single-stage — no low/high pair).
  • Gas supply and manifold vs this 80% plate.
  • Do not sit on hourly resets — find which step dies.
  • Watch one full try: inducer ramp, HSI, valve, flame, µA.

Plates that use E0

Same number, other makers

E0 on Amana is not the same code on these plates.