LockoutRetry / recycle lockout
Failed to sense flame after the retry limit (typically three trials). One-hour-class auto retry.
Walk E0 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Airflow before you touch the limit
On Daikin DM80VC a limit is airflow or overfire until proven otherwise. Do not replace the limit first. Filter, blower wheel, A-coil, and the heat-speed setting for THIS motor (tap, model plug, or communicating CFM — not a sister SKU chart). Watch one full try: inducer, HSI, valve, flame, µA.
Expect: Rise in the rating-plate window. Static vs this cabinet’s blower chart.
The rest of the walkthrough is Diagnose.
On the plates
- Watch one full try: inducer, HSI, valve, flame, µA.
- Gas supply and manifold low then high.
- Do not keep resetting — find which step dies.
- Full try at the percent it is attempting. A valve that will not come off minimum looks like E0/E6.
- Gas supply, HSI, rod, ground.
Plates that use E0
Same number, other makers
E0 on Daikin is not the same code on these plates.