LockoutRetry / recycle lockout
Too many failed ignition attempts or flame losses on this call.
Walk E0 in Diagnose
9 plates — walk the one on the cabinet
First check
1 Measure µA while it is running
Do not clean first and guess. Series-µA the rod on Goodman GMEC96 during a call. Falling µA is oxide, ground, or a dying flame. A hard drop is often the pressure switch or limit opening, not the rod. Watch one full try: inducer, HSI, valve, flame, µA.
Expect: Typically ≥ 1.0 µA DC on this family — confirm the door card. Rising while running.
The rest of the walkthrough is Diagnose.
On the plates
- Watch one full try: inducer, HSI glow, valve click, flame, µA.
- Gas supply and manifold (low then high).
- Ground and flame-rod cleanliness.
- Do not keep resetting — find which step dies.
- Watch one full try: inducer, HSI, valve, flame, µA. Which step dies?
- Gas supply and manifold low then high.
- Do not keep resetting the hour — find the failed step.
- Watch one full try: inducer, HSI, valve, flame, µA.
Plates that use E0