Amana
b2 / b3 / b9
ProtectMotor HP / limiting / low CFM
b2 = motor HP does not match the shared-data set. b3 = motor folding back on power/speed/temp. b9 = airflow below calculated minimum.
Walk b2 / b3 / b9 in Diagnose
2 plates — walk the one on the cabinet
First check
1 Read the plug / card on THIS cabinet
On Amana AMVM97 the model plug or shared-data card must match this cabinet size. A 100 kBtu plug in an 80 cabinet overfires and limits. A leftover memory card after a control swap throws d0/d4-class codes. Correct AMVM97 motor and memory card.
Expect: Plug / card part matches the rating plate and the replacement control bulletin.
The rest of the walkthrough is Diagnose.
On the plates
- Correct AMVM97 motor and memory card.
- Static, filter, coil. CFM follows modulating rate — a brick duct still b9s.
- Wrong CoolCloud outdoor type / CFM table.
Plates that use b2 / b3 / b9
Same number, other makers
b2 / b3 / b9 on Amana is not the same code on these plates.