Amana
b4 / b5 / b7
LockoutMotor trip / locked rotor / failed start
b4 = lost rotor or overload trip (shuts down and retries). b5 = locked rotor after 10 start attempts. b7 = motor parameters missing or failed to start after 40 attempts.
Walk b4 / b5 / b7 in Diagnose
3 plates — walk the one on the cabinet
First check
1 Is the wheel free?
Spin the Amana AMVC96 blower by hand. Ice, debris, or a seized bearing is not a control problem. Confirm the motor type on this plate — serial ECM, 9-speed tap, or X-13 — before you grab a capacitor. Wheel rub, debris in the housing, seized bearings.
Expect: Wheel free. Correct motor family for this IFC.
The rest of the walkthrough is Diagnose.
On the plates
- Wheel rub, debris, seized bearings.
- Static so high the motor cannot start the wheel — prove TES before a motor.
- Harness intermittents look like b7. Prove the 14-pin before a motor or IFC.
- Wheel rub, debris in the housing, seized bearings.
- Static so high the motor cannot start the wheel.
- Adjacent b-codes on some door cards are the same family — same harness/static/motor path.
Plates that use b4 / b5 / b7
Same number, other makers
b4 / b5 / b7 on Amana is not the same code on these plates.