Rheem codes

Rheem

33

Hazard

Rollout

Flame containment. Manual reset.

Walk 33 in Diagnose

8 plates — walk the one on the cabinet

First check

1 Treat this as flame outside the exchanger

Do not reset the Rheem R801S rollout and walk away. Write the code, kill the call, and look for flame at the burners, crossover, and vestibule before you do anything else.

Expect: No flame outside the exchanger. Burners seated. Crossover lit.

If pass: Still inspect secondary / flue / condensate before you reset.

The rest of the walkthrough is Diagnose.

On the plates

  • Exchanger, burners, flue, blocked secondary / collector.
  • Reset only after the cause is fixed. Recurring 33 is a CO / fire call.
  • Exchanger, burners, flue. Do not keep resetting.
  • Exchanger, burners, flue / chimney. Spillage is a fail.
  • Exchanger, burners, flue. Spillage / blocked chimney.

Plates that use 33

Same number, other makers

33 on Rheem is not the same code on these plates.