York
Slow green
StatusNormal, no heat call
Idle, powered.
Walk Slow green in Diagnose
5 plates — walk the one on the cabinet
First check
1 Confirm this is not a fault
On the York TM8T this readout (Slow green) is run status, not a lockout. Write what the display actually shows and whether W/Y/G is present at the IFC.
Expect: Idle / Ht / CF / stage+CFM words change when you apply and remove the call.
If fail: If the word never changes on a real call, the call is not reaching this IFC.
If pass: The board is alive. Diagnose the comfort complaint, not this code.
The rest of the walkthrough is Diagnose.
On the plates
- If the house is cold, the call never reached W. Check R/W at the IFC, door switch, and the thermostat.
- LED off is no 120/24 — not this code.
- No W at the IFC if the house is cold.
- W path if the house is cold.