York codes

York

7 red

Lockout

Flame not established after 3 tries

Ignition retries exceeded.

Walk 7 red in Diagnose

5 plates — walk the one on the cabinet

First check

1 Watch one full try — do not reset

Write the York TM8T code. Watch inducer, HSI glow, valve click, flame, µA. The step that dies is the repair. Resetting only burns another try into a harder lockout. HSI, gas, rod, ground.

Expect: W1 → W2 → Limit

The rest of the walkthrough is Diagnose.

On the plates

  • Watch one full try: inducer, HSI glow, valve click, flame, µA.
  • Gas supply and manifold (low then high). Gas cock, LP tank, meter lock.
  • Igniter 120 VAC and ohms. Open circuit is 12-red — if you have 7-red the igniter usually glowed.
  • Rod, ground, and 9-red polarity if µA is near zero.
  • HSI glow and 120 VAC, gas, rod µA, ground.
  • HSI, gas, rod, ground.

Plates that use 7 red