Mitsubishi codes

Mitsubishi

EA

Lockout

4-way valve

Did not shift or sensor disagrees.

Walk EA in Diagnose

3 plates — walk the one on the cabinet

First check

1 Confirm O/B is energized the way THIS outdoor expects

Most US splits energize O in cool. Some Rheem/Ruud energize B in heat. Read the Mitsubishi MSZ-FS diagram, not a generic heat-pump card. Solenoid voltage during the call, pressure swap, suction temp.

Expect: Correct 24 V at the solenoid for the mode that is failing.

The rest of the walkthrough is Diagnose.

On the plates

  • Solenoid voltage during the call, pressure swap, suction temp.
  • Solenoid voltage, pressure swap, suction temp.
  • Solenoid voltage during a heat/cool changeover.
  • Pressure swap at the outdoor. A branch box does not replace the 4-way.

Plates that use EA

Same number, other makers

EA on Mitsubishi is not the same code on these plates.