EA
Lockout4-way valve
Did not shift or sensor disagrees.
Walk EA in Diagnose
3 plates — walk the one on the cabinet
First check
1 Confirm O/B is energized the way THIS outdoor expects
Most US splits energize O in cool. Some Rheem/Ruud energize B in heat. Read the Mitsubishi MSZ-FS diagram, not a generic heat-pump card. Solenoid voltage during the call, pressure swap, suction temp.
Expect: Correct 24 V at the solenoid for the mode that is failing.
The rest of the walkthrough is Diagnose.
On the plates
- Solenoid voltage during the call, pressure swap, suction temp.
- Solenoid voltage, pressure swap, suction temp.
- Solenoid voltage during a heat/cool changeover.
- Pressure swap at the outdoor. A branch box does not replace the 4-way.