Carrier
ABCD
LockoutCommunication
Wall control or outdoor dropped off the bus.
Walk ABCD in Diagnose
5 plates — walk the one on the cabinet
First check
1 Data pair, not 24 V
On Carrier 58CVA indoor/outdoor comm is a data pair (AB, S1/S2, U, ComfortBridge, ComfortLink — whatever THIS plate uses). It is not a 24 V Y. Check polarity, continuity, and that nobody landed it on R/C. A/B/C/D, polarity, C required, no 24V on D.
Expect: Pair continuous, not shorted to chassis, polarity per the diagram.
The rest of the walkthrough is Diagnose.
On the plates
- A/B/C/D landing, polarity, only one Infinity control, no 24V on D.
- C present — Infinity still needs C. A 24V stat on ABCD will not drive modulation and may lock the IFC.
- Outdoor Greenspeed / Infinity pair dropped? Check the outdoor events too.
- C present. A 24V Performance stat on this IFC will not stage it like a 59TP6.
- Outdoor pair on the same bus — a dead Greenspeed looks like indoor comm loss until you read events.
- A/B/C/D, polarity, C required, no 24V on D.
- Non-communicating 58CVX cousins may be 24V — read the actual board.
Plates that use ABCD
Same number, other makers
ABCD on Carrier is not the same code on these plates.