Rheem
93
LockoutInternal control
IFC self-fault.
Walk 93 in Diagnose
7 plates — walk the one on the cabinet
First check
1 Write the live code and watch one cycle
On Rheem R951T read Rheem/Ruud 2-digit IFC (TA / CT) before you pull power. Write 93 exactly. Watch one full sequence and note which step dies. Write every stored code first. 93 after 11/45/57 is often a drowned or hammered board, not a first-swap.
Expect: W1: Inducer low → 45 if the low/intake switch never closes → HSI → valve → 11 if no prove, 12/13 if flame is weak or drops.
The rest of the walkthrough is Diagnose.
On the plates
- Write every stored code first. 93 after 11/45/57 is often a drowned or hammered board, not a first-swap.
- Line voltage, polarity (26), wet control from a 96% leak.
- Stored stack first. Wet board, polarity (26), persistent input.
- Do not confuse 93 with an EcoNet-stat blank.
- Stat log + board digits. Persistent 93 after a clean power-up is the control.
- Wet board from a 98% leak, polarity, leftover 24V landing on the data pair.