Lennox
E273
LockoutSoft lockout — last recycle flame failure
Lost flame after it had proven.
Walk E273 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Measure µA while it is running
Do not clean first and guess. Series-µA the rod on Lennox EL195NE during a call. Falling µA is oxide, ground, or a dying flame. A hard drop is often the pressure switch or limit opening, not the rod. F-menu µA, rod, ground, manifold after blower-on. Flame that dies when the wheel starts is often draft or a weak rod.
Expect: Flame (F menu): µA per EL296 card. Rising while running.
The rest of the walkthrough is Diagnose.
On the plates
- F-menu µA, rod, ground, manifold after blower-on. Flame that dies when the wheel starts is often draft or a weak rod.
- Pairs with E240.
- Rod µA, ground, manifold after blower-on.