Lennox
E270
LockoutSoft lockout — max retries, no flame current
Never saw flame current.
Walk E270 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Measure µA while it is running
Do not clean first and guess. Series-µA the rod on Lennox EL195NE during a call. Falling µA is oxide, ground, or a dying flame. A hard drop is often the pressure switch or limit opening, not the rod. Watch a try: inducer, HSI glow, valve click, flame, then F-menu µA. Which step dies?
Expect: Flame (F menu): µA per EL296 card. Rising while running.
The rest of the walkthrough is Diagnose.
On the plates
- Watch a try: inducer, HSI glow, valve click, flame, then F-menu µA. Which step dies?
- This is ignition, not rollout. The older field rumor that E270 ‘is rollout’ is wrong on this SureLight family — rollout lives in the E250 / E274 string.
- Watch a try. HSI, gas, rod. Not rollout.