Lennox
E240
ProtectLow flame current — run mode
Flame is present but µA is below the run threshold.
Walk E240 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Measure µA while it is running
Do not clean first and guess. Series-µA the rod on Lennox EL195NE during a call. Falling µA is oxide, ground, or a dying flame. A hard drop is often the pressure switch or limit opening, not the rod. F menu for live µA. Clean the rod — not sandpaper. Neutral-to-ground and E117.
Expect: Flame (F menu): µA per EL296 card. Rising while running.
The rest of the walkthrough is Diagnose.
On the plates
- F menu for live µA. Clean the rod — not sandpaper. Neutral-to-ground and E117.
- Clears at the end of the heat call. Repeating E240 becomes E270 / E273.
- F menu, rod, ground. Repeating E240 becomes E270 / E273.