Lennox codes

Lennox

E229

Status

Ignition on high fire

Low PS did not close; IFC lit on high. OEM: not a separate high-fire repair.

Walk E229 in Diagnose

5 plates — walk the one on the cabinet

First check

1 Prove inducer and the live code

Do not pull power — that clears the Lennox EL195NE active code. Write E229. Is the inducer spinning on this call? Silent inducer is not a pressure switch. This is a low-fire draft problem wearing a high-fire costume. Fix E223 / E227 physics. Do not start on the high-fire manifold screw.

Expect: Inducer port: Open to the collector, not packed with oxide. Two hoses, never teed.

If fail: 120 VAC missing → IFC / door switch / incoming power. Voltage + dead motor → inducer.

If pass: Inducer running + this code → trap, hose, switch, vent (step 2).

The rest of the walkthrough is Diagnose.

On the plates

  • This is a low-fire draft problem wearing a high-fire costume. Fix E223 / E227 physics. Do not start on the high-fire manifold screw.
  • Also fires on high for ~60 s if continuous fan was already on (heat-exchanger warmup) — that one is information only.
  • Fix E223 physics. Do not start on the high-fire manifold screw.
  • Same metal-vent path as E223. Do not start on the high-fire manifold screw.

Plates that use E229