Lennox
E228
LockoutCombustion air inducer calibration failure
Could not finish PS calibration.
Walk E228 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Is the wheel free?
Spin the Lennox EL195NE blower by hand. Ice, debris, or a seized bearing is not a control problem. Confirm the motor type on this plate — serial ECM, 9-speed tap, or X-13 — before you grab a capacitor. Vent and both hoses seated. Inducer must be able to sweep both switches.
Expect: Wheel free. Correct motor family for this IFC.
The rest of the walkthrough is Diagnose.
On the plates
- Vent and both hoses seated. Inducer must be able to sweep both switches.
- Fix E223/E225 physics first — calibration will not pass on a clogged port.
- Fix the port and hoses first. Calibration will not pass on a clogged collector.