LockoutLow PS opened during trial or run
Low switch had closed, then opened mid-trial or in run.
Walk E227 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Prove inducer and the live code
Do not pull power — that clears the Lennox EL195NE active code. Write E227. Is the inducer spinning on this call? Silent inducer is not a pressure switch. Wind, ice, trap siphon, inducer dropping out after light-off.
Expect: Inducer port: Open to the collector, not packed with oxide. Two hoses, never teed.
If fail: 120 VAC missing → IFC / door switch / incoming power. Voltage + dead motor → inducer.
If pass: Inducer running + this code → trap, hose, switch, vent (step 2).
The rest of the walkthrough is Diagnose.
On the plates
- Wind, ice, trap siphon, inducer dropping out after light-off.
- Same port-clean as E223 — a half-clogged port will make then drop.
- Wind, ice, trap siphon, half-clogged inducer port.