Lennox codes

Lennox

E223

Lockout

Low PS failed OPEN

Low-fire pressure path did not make.

Walk E223 in Diagnose

4 plates — walk the one on the cabinet

First check

1 Prove inducer and the live code

Do not pull power — that clears the Lennox EL195NE active code. Write E223. Is the inducer spinning on this call? Silent inducer is not a pressure switch. Inducer actually on low? Low-fire hose only, 96% trap, PVC intake/exhaust.

Expect: Inducer port: Open to the collector, not packed with oxide. Two hoses, never teed.

If fail: 120 VAC missing → IFC / door switch / incoming power. Voltage + dead motor → inducer.

If pass: Inducer running + this code → trap, hose, switch, vent (step 2).

The rest of the walkthrough is Diagnose.

On the plates

  • Inducer actually on low? Low-fire hose only, 96% trap, PVC intake/exhaust.
  • Clean the inducer pressure port — known EL296. Dust packs the port and throws the whole PS family.
  • Trap, PVC, low hose, inducer port (same known EL296 clog).
  • Two hoses, never teed.

Plates that use E223