Goodman
E4
HazardFlame when valve should be off
Rod sees flame with both solenoids de-energized.
Walk E4 in Diagnose
9 plates — walk the one on the cabinet
First check
1 Shut the gas cock first
On Goodman GMEC96 the rod sees flame with the valve de-energized. Shut the cock. If flame stays, the valve is leaking — replace it. Do not jump or energize it as a test. Shut the gas cock. Leaking valve — replace, do not jump.
Expect: Flame dies when the cock is shut.
If fail: Leaking valve. Replace. Do not leave the unit.
The rest of the walkthrough is Diagnose.
On the plates
- Shut the gas cock. If flame stays, leaking valve — replace, do not jump.
- Rod shorted to ground or IFC flame circuit.
- Shut the gas cock. Leaking valve — replace, do not jump.
- Shut the gas cock. If flame stays, leaking modulator — replace, do not drive it as a test.
- Treat as a hazard until the valve is proven closed.