LockoutFailed outdoor fan
Fan not following the drive. Head pressure climbs, HPS or inverter OH follows.
Walk Outdoor fan in Diagnose
2 plates — walk the one on the cabinet
First check
1 Let it cool, then read the drive LED
On Trane XV18 overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. Command vs spin. Fan motor and drive output — there is no dual run cap to throw first.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
The rest of the walkthrough is Diagnose.
On the plates
- Command vs spin. Fan motor and drive output — there is no dual run cap to throw first.
- Debris, ice, seized bearing.