LockoutIndoor blower HP / unit capacity mismatch
Programmed unit size does not match the motor horsepower the IFC sees.
Walk E202 in Diagnose
2 plates — walk the one on the cabinet
First check
1 Read the plug / card on THIS cabinet
On Lennox EL195NE the model plug or shared-data card must match this cabinet size. A 100 kBtu plug in an 80 cabinet overfires and limits. A leftover memory card after a control swap throws d0/d4-class codes. P menu: pick the character for THIS cabinet, hold to store, let the IFC reset.
Expect: Plug / card part matches the rating plate and the replacement control bulletin.
The rest of the walkthrough is Diagnose.
On the plates
- P menu: pick the character for THIS cabinet, hold to store, let the IFC reset.
- An EL296E constant-torque motor in this VS cabinet will throw E202 / E310. Use the VS motor.