Defrost sensor / stuck in defrost

Lockout

Defrost path

Outdoor coil sensor open/short/out of range, or the board will not leave defrost (fan off, RV shifted to cool, long steam).

First check

1 Is it actually in defrost?

On Goodman GSZC18 confirm the board thinks it is in defrost: OD fan off, RV shifted, indoor calling heat/aux. A failed OD fan in heat ices the coil and looks like a defrost board. Ohms the outdoor coil / defrost sensor vs the board chart. Unplugged sensor is a stuck-defrost classic.

Expect: Defrost only with a cold outdoor coil, not on every call.

The rest of the walkthrough is Diagnose.

On the plates

  • Ohms the outdoor coil / defrost sensor vs the board chart. Unplugged sensor is a stuck-defrost classic.
  • Board initiating defrost on time with a warm coil? Bad sensor or bad board — prove the sensor first.
  • Outdoor fan must restart when defrost terminates. A dead fan motor ices the coil again on the next heat call.

Plates that use Defrost sensor / stuck in defrost