Goodman
b2
LockoutHP mismatch vs shared data
Connected motor horsepower does not match the value in the furnace shared-data set. Furnace will not operate.
Walk b2 in Diagnose
4 plates — walk the one on the cabinet
First check
1 Read the plug / card on THIS cabinet
On Goodman GMVC80 the model plug or shared-data card must match this cabinet size. A 100 kBtu plug in an 80 cabinet overfires and limits. A leftover memory card after a control swap throws d0/d4-class codes. Wrong replacement motor for this cabinet size.
Expect: Plug / card part matches the rating plate and the replacement control bulletin.
The rest of the walkthrough is Diagnose.
On the plates
- Compare motor HP stamp to the furnace model and the shared-data card.
- After an IFC or motor swap, the card from the old board must travel with the cabinet size.
- A ¾ HP motor in a 1 HP cabinet (or the reverse) throws b2 even when the wheel spins.
- Motor HP stamp vs this GMVM97 size and the card on the IFC.
- A GMVC96 two-stage motor/card mix throws b2/d4 even when the wheel would spin.
- Wrong replacement motor for this cabinet size.
- Wrong memory card after an IFC swap (see d0/d4).
- Do not ‘make it work’ with a different HP ECM — ComfortBridge CFM tables are card-specific.
Plates that use b2
Same number, other makers
b2 on Goodman is not the same code on these plates.