Goodman
9 flash
LockoutPolarity / ground
L1/N or chassis ground. Sister to rapid flash on some revisions.
Walk 9 flash in Diagnose
Sign in for the next measurement
First check
1 Hot and neutral at the IFC, not the disconnect
On Goodman GMSS96 polarity/ground is measured at the board. A correctly landed disconnect with a swapped whip at the IFC still throws this. Hot/neutral at the IFC.
Expect: L1 hot, N neutral, ~120 VAC L1 to N, ~0 VAC N to ground.
The rest of the walkthrough is Diagnose.
On the plates
- Hot/neutral at the IFC.
- Burner box to IFC ground screw.
Plates that use 9 flash
Same number, other makers
9 flash on Goodman is not the same code on these plates.