Daikin
HPS
LockoutHigh pressure
Outdoor airflow, overcharge, or restriction.
Walk HPS in Diagnose
4 plates — walk the one on the cabinet
First check
1 Heat rejection first
On Daikin DC5SE high pressure is outdoor airflow until proven otherwise. Fan running the right direction, coil clean, fins not folded, no recirc over a fence or through a garage. Fan running? Coil dirty? SC vs nameplate on a TXV coil.
Expect: OD fan on, coil clean, discharge air leaving the top/side freely.
The rest of the walkthrough is Diagnose.
On the plates
- Outdoor fan actually running? Coil dirty?
- Indoor airflow on the communicating CFM tables.
- Weigh-in on inverter SKUs. SC window only if you have confirmed a two-stage TXV sibling.
- Outdoor fan running? Coil dirty, recirc, bent fins.
- Subcooling vs indoor TXV sheet. Liquid-line drier / restriction.
- Do not keep resetting HPS into a locked fan.
- Fan running? Coil dirty? SC vs nameplate on a TXV coil.
Plates that use HPS
Same number, other makers
HPS on Daikin is not the same code on these plates.