Carrier
21
LockoutGas-heat lockout / model plug
Valve relay fault, or missing/wrong model plug on boards that use one.
Walk 21 in Diagnose
7 plates — walk the one on the cabinet
First check
1 Read the plug / card on THIS cabinet
On Carrier 58SP0 the model plug or shared-data card must match this cabinet size. A 100 kBtu plug in an 80 cabinet overfires and limits. A leftover memory card after a control swap throws d0/d4-class codes. Most Comfort 80 STA boards are not TP6-style plug cabinets — check the door before you hunt a plug.
Expect: Plug / card part matches the rating plate and the replacement control bulletin.
The rest of the walkthrough is Diagnose.
On the plates
- Model plug seated for THIS 59TP6 cabinet. Wrong plug = wrong CFM and false 41/44.
- Miswired valve.
- Valve harness and 24 VAC during trial.
- If this cabinet has a model plug, it must match THIS Comfort 96 cabinet — do not steal a 59TP6 plug and expect correct CFM.
- Most Comfort 80 STA boards are not TP6-style plug cabinets — check the door before you hunt a plug.
Plates that use 21
Same number, other makers
21 on Carrier is not the same code on these plates.