Carrier codes

Carrier

13

Lockout

Limit lockout

Hardened 33. Limit/rollout stayed open.

Walk 13 in Diagnose

7 plates — walk the one on the cabinet

First check

1 Treat this as flame outside the exchanger

Do not reset the Carrier 58SP0 rollout and walk away. Write the code, kill the call, and look for flame at the burners, crossover, and vestibule before you do anything else.

Expect: No flame outside the exchanger. Burners seated. Crossover lit.

If pass: Still inspect secondary / flue / condensate before you reset.

The rest of the walkthrough is Diagnose.

On the plates

  • Treat as a hardened 33. Filter, static, rise, rollout reset.
  • Treat as a hardened 33. Filter, heat speed / 18-speed tap, rise, rollout reset.
  • Filter, heat speed, dirty A-coil, rollout reset.

Plates that use 13

Same number, other makers

13 on Carrier is not the same code on these plates.