Bosch
AHU heat limit
ProtectElectric heat limits on the BVA
Strip kit opened a limit / sequencer. This is AHU airflow or a bad element, not a BOVA P-code.
Walk AHU heat limit in Diagnose
Sign in for the next measurement
First check
1 Is aux actually being requested?
On Bosch BOVA 2.0 confirm W / E / aux at the indoor control. A heat-pump call with a communicating board that thinks it needs strips is a config / outdoor issue first. Filter, blower, heat-kit size vs the BVA nameplate.
Expect: Aux request present only when it should be.
The rest of the walkthrough is Diagnose.
On the plates
- Filter, blower, heat-kit size vs the BVA nameplate.
- W at the AHU calling strips because HP failed (RV, sensors, ATL) — fix the HP before you upsize strips.
- No Carrier 33 and no Daikin E3 on this limit string.