Trane
Inverter OC / OH
LockoutDrive overcurrent / overheat (drive LED)
Outdoor inverter protection. Read the drive LED / ComfortLink text. Not a contactor or dual-cap failure.
Walk Inverter OC / OH in Diagnose
2 plates — walk the one on the cabinet
First check
1 Let it cool, then read the drive LED
On Trane XV18 overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. Compressor to ground and winding integrity. Heat sink / drive cooling path.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
The rest of the walkthrough is Diagnose.
On the plates
- Compressor to ground and winding integrity. Heat sink / drive cooling path.
- Supply voltage at the outdoor (208–230 class). Brownout plus a long line-set is a real trip.
- Weigh-in vs nameplate before you condemn a drive on a charge-related overcurrent.