Stat, indoor, or data pair dropped. The communicating thermostat is the system.
Walk EcoNet in Diagnose
2 plates — walk the one on the cabinet
First check
1 Data pair, not 24 V
On Rheem R98MV indoor/outdoor comm is a data pair (AB, S1/S2, U, ComfortBridge, ComfortLink — whatever THIS plate uses). It is not a 24 V Y. Check polarity, continuity, and that nobody landed it on R/C. Data-pair landing and polarity. EcoNet is not R/W.
Expect: Pair continuous, not shorted to chassis, polarity per the diagram.
The rest of the walkthrough is Diagnose.
On the plates
- Data-pair landing and polarity. EcoNet is not R/W.
- 24 VAC still required at the control — comm dead is not ‘no transformer’ until you measure.
- One EcoNet control. Do not stack a 24V stat on the data pins.
- Stat diagnostics before you condemn the IFC.