Mitsubishi
F3
ProtectDischarge thermistor
Outdoor discharge.
Walk F3 in Diagnose
3 plates — walk the one on the cabinet
First check
1 Which sensor is this code?
On Mitsubishi MSZ-FS F3 is a specific thermistor — indoor return/pipe, outdoor coil, discharge, or ambient. Unplug that sensor and ohm it vs the OEM temperature/resistance chart. Ohms. If the reading is real, high SH / low charge / overcharge per mode.
Expect: Ohms move with temperature. Not open, not shorted.
The rest of the walkthrough is Diagnose.
On the plates
- Ohms. If the reading is real, high SH / low charge / overcharge per mode.
- Ohms on the outdoor. Real high discharge → charge / airflow / overcharge per mode.
- Ohms the discharge thermistor.
- If the reading is real: overcharge, low airflow across the running indoors, or restriction.