Lennox
E223 / E225
LockoutPressure / inducer band
Modulating prove failed at that rate. Stat may say low/high PS even though the hardware is a band, not two EL296 discs.
Walk E223 / E225 in Diagnose
2 plates — walk the one on the cabinet
First check
1 Prove inducer and the live code
Do not pull power — that clears the Lennox SL297NV active code. Write E223 / E225. Is the inducer spinning on this call? Silent inducer is not a pressure switch. Vent, trap, inducer, hose. 96% PVC physics.
Expect: 120 VAC at the inducer on a heat call. Wheel turning.
If fail: 120 VAC missing → IFC / door switch / incoming power. Voltage + dead motor → inducer.
If pass: Inducer running + this code → trap, hose, switch, vent (step 2).
The rest of the walkthrough is Diagnose.
On the plates
- Vent, trap, inducer, hose. 96% PVC physics.
- Do not treat it as a two-stage W1/W2 swap.