Goodman
VFD
LockoutVFD / indoor-fan drive
The indoor fan is a drive, not a contactor + cap. Type the keypad string: oC, Uv, ov, GF, oH, PF.
Walk VFD in Diagnose
Sign in for the next measurement
First check
1 Read the drive before you cycle power
On Goodman GPG16 photograph the VFD keypad or the unit-board fan alarm (OC, LU, OU, GF, OH, limp). Power-cycle wipes what you needed. Photograph the drive keypad before you cycle power. Yaskawa/ABB show oC / Uv / ov; EcoBlue / Reliatel may say fan fail instead.
Expect: Live drive code written down. Line voltage at L1/L2/L3 of the drive.
The rest of the walkthrough is Diagnose.
On the plates
- Photograph the drive keypad before you cycle power. Yaskawa/ABB show oC / Uv / ov; EcoBlue / Reliatel may say fan fail instead.
- Enable present? Speed reference present? Motor spinning and proving?
- Do not throw a dual run cap at a VFD motor.
Plates that use VFD
Same number, other makers
VFD on Goodman is not the same code on these plates.