Goodman
idle / Ht / CF
StatusStatus, not a fault
Normal run states. idle = standby. Ht = heat running (capacity is a percent, not Ht1/Ht2 stages). CF = continuous fan.
Walk idle / Ht / CF in Diagnose
Sign in for the next measurement
First check
1 Confirm this is not a fault
On the Goodman GRVM97 this readout (idle / Ht / CF) is run status, not a lockout. Write what the display actually shows and whether W/Y/G is present at the IFC.
Expect: Idle / Ht / CF / stage+CFM words change when you apply and remove the call.
If fail: If the word never changes on a real call, the call is not reaching this IFC.
If pass: The board is alive. Diagnose the comfort complaint, not this code.
The rest of the walkthrough is Diagnose.
On the plates
- Do not replace the board because it says Ht or CF.
- Ht that never climbs off a low rate is a prove / valve / menu problem, not a ‘stuck Ht1’ two-stage code.
Plates that use idle / Ht / CF
Same number, other makers
idle / Ht / CF on Goodman is not the same code on these plates.