Goodman
HPS / LPS
LockoutPressure
Airflow or charge.
Walk HPS / LPS in Diagnose
2 plates — walk the one on the cabinet
First check
1 Heat rejection first
On Goodman GSZ14 high pressure is outdoor airflow until proven otherwise. Fan running the right direction, coil clean, fins not folded, no recirc over a fence or through a garage. Coil, fan, indoor airflow in heat (often the missed one).
Expect: OD fan on, coil clean, discharge air leaving the top/side freely.
The rest of the walkthrough is Diagnose.
On the plates
- Coil, fan, indoor airflow in heat (often the missed one).
- Charge by SH/SC for this piston/TXV pair — not a GSZC18 weigh-in.
- Coil, fan, charge by weigh-in — you do not ‘top off’ a Greenspeed.
- Outdoor fan that is actually the inverter-driven fan, not a dual-cap PSC motor.
- Do not use 24ACC6 piston superheat as the pass/fail.
Plates that use HPS / LPS
Same number, other makers
HPS / LPS on Goodman is not the same code on these plates.