Goodman
d0 / d4
LockoutShared data / memory card
d0 = IFC has no shared-data set (replacement board, missing card) and cannot drive the serial ECM or calculate CFM. d4 = card rejected (wrong model card).
Walk d0 / d4 in Diagnose
3 plates — walk the one on the cabinet
First check
1 Read the plug / card on THIS cabinet
On Goodman GMVC80 the model plug or shared-data card must match this cabinet size. A 100 kBtu plug in an 80 cabinet overfires and limits. A leftover memory card after a control swap throws d0/d4-class codes. After an IFC swap the AMVC96 memory card must be installed and seated.
Expect: Plug / card part matches the rating plate and the replacement control bulletin.
The rest of the walkthrough is Diagnose.
On the plates
- After an IFC swap the AMVC96 memory card must be installed and seated.
- A GMVC96 card usually twins; an AMVM97, AVPTC, or AR9T96 card is d4.
- Do not run the furnace on empty shared data and guess CFM.
- Install the AMVM97 card, not an AMVC96 two-stage card.
- GMVM97 twin card is the usual cross. AVPTC / AR9T96 cards are d4.
- Empty tables will not drive the serial ECM or calculate CFM.