Goodman
5 flash
HazardFlame with valve off
Leaking valve or false flame sense.
Walk 5 flash in Diagnose
Sign in for the next measurement
First check
1 Shut the gas cock first
On Goodman GMSS96 the rod sees flame with the valve de-energized. Shut the cock. If flame stays, the valve is leaking — replace it. Do not jump or energize it as a test. Shut the gas cock. If flame stays, replace the valve.
Expect: Flame dies when the cock is shut.
If fail: Leaking valve. Replace. Do not leave the unit.
The rest of the walkthrough is Diagnose.
On the plates
- Shut the gas cock. If flame stays, replace the valve.
- Rod shorted to ground.
Plates that use 5 flash
Same number, other makers
5 flash on Goodman is not the same code on these plates.