LockoutDrive overcurrent / overheat
L5/L4-class faults on the drive.
Walk Inverter in Diagnose
Sign in for the next measurement
First check
1 Let it cool, then read the drive LED
On Daikin DC9VS overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. Compressor to ground, heat sink, supply voltage. Weigh-in vs nameplate.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
The rest of the walkthrough is Diagnose.
On the plates
- Compressor to ground, heat sink, supply voltage. Weigh-in vs nameplate.
- These L-codes do not exist on 24ACC6. If you are looking at a contactor, you are on the wrong outdoor.
Plates that use Inverter
Same number, other makers
Inverter on Daikin is not the same code on these plates.