York Affinity YXV inverter air conditioner. Outdoor drive. No reversing valve. Charge is weigh-in. Not YXT two-stage.
Not YXT two-stage. Not YC2E / YC2F LX. Not a York heat-pump YZF / YH (RV + defrost).
Drive
Inverter scroll · variable capacity
Bus
Affinity / Hx communicating when paired
Charge
Weigh-in + line-set
This board
Affinity outdoor inverter — AC only
- Affinity events / outdoor drive.
- No dual cap. No defrost.
- YXT is the two-stage Affinity.
Affinity last events. Drive last-fault if the stat is blank.
Universal swap
York YXV outdoor. No furnace IFC universal. Replace the OEM outdoor control / contactor / drive by the silk.
Silk: YXV
White-Rodgers
—ICM
—Honeywell
—- Indoor furnace universals (50A55, 50M56U, ICM282B, ICM2811, S9200U). This is not an IFC.
- Do not ‘adapt’ a furnace board to an outdoor inverter, defrost PCB, or contactor.
After you pull the dead card
- 1Photograph the outdoor silk. Indoor 50A55 / ICM282B / S9200U do not belong here.
- 2Contactor units: replace the contactor / cap / HPS — there is no universal outdoor board.
- 3Inverter / communicating outdoors: OEM drive only. There is no White-Rodgers or ICM outdoor universal.
Field wiring
Written landings for York YXV. Not a factory schematic.
York YXV. Affinity communicating inverter. YC2E / YC2F are 24V LX. YXT is two-stage, not this drive.
Written circuit description only — FieldBench does not redraw maker schematics. Example: R to W closes on a heat call; verify 24V at W1 before you change the IFC.
Open manufacturer PDFThis indoor
Affinity / Hx indoor. YC2E Y/C is the wrong book.
Affinity pair
Affinity / Hx wall control and a matching indoor.
Affinity / Hx control
Communicating pair on the silk. Do not invent a pin number.
- DATAAffinity / Hx pairData
- R24V if the control needs it24V
- CCommon24V
YXV outdoor drive
Photograph the outdoor comm silk. No dual cap.
- DATAAffinity pair on the silkData
Outdoor line — inverter drive
208/230 into the drive. No contactor slam. DC bus can stay live after the disconnect.
- L1Line to the driveLine
- L2Line to the driveLine
- GNDEquipment groundLine
Landing
- DataControl pairindooroutdoor pair
Data. Not Y.
- LineL1 / L2drive
208/230
Prove it
- Affinity control lists the outdoor. Bus vs drive before gauges.
- Read the outdoor silk for the pair.
Do not
- Do not use the YC2E Y/C diagram on YXV.
- Do not invent Hx3 pin numbers.
Affinity pair only — no unpublished York pinout.
Sequence
- 1
Call
Indoor requests capacity. Inverter ramps.
- 2
Protect
HPS / LPS / drive. No defrost.
Faults on this IFC
Step 1, then 2, then 3. Expected reading and the fail branch sit under each check.
Comm
ABCD / outdoor drop
Drive or bus. Wall control loses the outdoor.
1 Let it cool, then read the drive LED
On York YXV overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. ABCD landing and polarity, outdoor board power, inverter comms harness.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
2 Voltage and compressor windings
Incoming voltage in range (this plate’s line-voltage code). Compressor windings even, no ground. A shorted compressor will kill a new drive. C still required at the wall control.
Expect: Balanced windings. No winding to ground. Line voltage stable under load.
3 Charge and the drive last
A starved or flooded compressor will overcurrent. Confirm SH/SC and charge weight. Only then condemn the inverter. Indoor must be Infinity-capable. A 24ACC6-style indoor pairing is the wrong mental model.
Expect: Charge on the nameplate. Drive code gone after a cool-down and a clean coil.
HPS / LPS
Pressure protection
Still real on an inverter.
1 Let it cool, then read the drive LED
On York YXV overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. Coil, fan, charge by weigh-in — you do not ‘top off’ a Greenspeed.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
2 Voltage and compressor windings
Incoming voltage in range (this plate’s line-voltage code). Compressor windings even, no ground. A shorted compressor will kill a new drive. Outdoor fan that is actually the inverter-driven fan, not a dual-cap PSC motor.
Expect: Balanced windings. No winding to ground. Line voltage stable under load.
3 Charge and the drive last
A starved or flooded compressor will overcurrent. Confirm SH/SC and charge weight. Only then condemn the inverter. Do not use 24ACC6 piston superheat as the pass/fail.
Expect: Charge on the nameplate. Drive code gone after a cool-down and a clean coil.
Inverter
Drive overcurrent / overheat
L5/L4-class faults on the drive.
1 Let it cool, then read the drive LED
On York YXV overcurrent / overheat is often a dirty coil, a failed OD fan, or a locked compressor — not a dead inverter. Clear airflow, confirm the OD fan, and read the drive LED before you order a control. Compressor to ground, heat sink, supply voltage. Weigh-in vs nameplate.
Expect: OD fan running. Coil clean. Drive LED decoded from THIS outdoor’s card.
2 Voltage and compressor windings
Incoming voltage in range (this plate’s line-voltage code). Compressor windings even, no ground. A shorted compressor will kill a new drive. These L-codes do not exist on 24ACC6. If you are looking at a contactor, you are on the wrong outdoor.
Expect: Balanced windings. No winding to ground. Line voltage stable under load.
3 Charge and the drive last
A starved or flooded compressor will overcurrent. Confirm SH/SC and charge weight. Only then condemn the inverter.
Expect: Charge on the nameplate. Drive code gone after a cool-down and a clean coil.
Workflows
Silent YXV
Indoor calling, outdoor not ramping.
1 Prove the call and the live code
Drive / Affinity events. No contactor to chase.
Expect: Write whatever Affinity outdoor inverter — AC only is showing. Affinity last events. Drive last-fault if the stat is blank.
If fail: No call at the IFC → stat / harness. Do not change gas parts.
2 Isolate the first failed step in the sequence
Weigh-in. Not a YC2E SH chart.
Expect: Protect: HPS / LPS / drive. No defrost.
3 Confirm with a number, then the next part
Plate YZF / YH = heat pump. Do not stay here.
Expect: Charge: Recover and weigh. Nameplate + ounces/ft. Not piston SH. · ABCD: Communicating to the Infinity indoor / 59MN7 family. D is not Y.
If fail: Stay on this plate. The out-of-range reading is the part.
If pass: Reading in range → the next step in this workflow is the repair.
Test points
Charge
Recover and weigh. Nameplate + ounces/ft. Not piston SH.
ABCD
Communicating to the Infinity indoor / 59MN7 family. D is not Y.
Drive
Inverter LEDs / last fault. No contactor coil 24 VAC test.
Gotchas
- YXT is one letter away and is two-stage, not this drive.
Related plates
Install this plate
Install York YXV as Affinity · inverter AC.
Affinity · inverter AC
This plate — not the sister SKU
- Not YXT two-stage. Not YC2E / YC2F LX. Not a York heat-pump YZF / YH (RV + defrost).
- YXT is one letter away and is two-stage, not this drive.
Control on this outdoor
- Affinity events / outdoor drive.
- No dual cap. No defrost.
- YXT is the two-stage Affinity.
Hardware
- Drive: Inverter scroll · variable capacity
- Bus: Affinity / Hx communicating when paired
- Charge: Weigh-in + line-set
First fire
- 1Drive / Affinity events. No contactor to chase.
- 2Weigh-in. Not a YC2E SH chart.
- 3Plate YZF / YH = heat pump. Do not stay here.
Do not on York YXV
- Not YXT two-stage. Not YC2E / YC2F LX. Not a York heat-pump YZF / YH (RV + defrost).
- YXT is one letter away and is two-stage, not this drive.
Maker literature
FieldBench does not host manufacturer files. Each link opens the maker’s own literature page in a new tab.
- York residential gas furnacesLiterature searchTM9 / TM8 family listing (Coleman / Luxaire share the JCI IFC). UPGNet holds the I/O.Open manufacturer PDF
- York / Bosch Home ComfortLiterature searchSearch York YXV on the maker’s literature page.Open manufacturer PDF
Warranty and bulletins
Affected models, serial range, symptom, remedy, date. Maker files open on the manufacturer site.
Residential limited warranty
dealerYork furnace warranty
Registered TM8 / TM9 furnace warranty · Dealer claims portal
Dealer portals
dealerWhere remaining service letters live
Current-year service letters not on a public literature page · Maker dealer portal