Daikin FIT / ComfortNet inverter AC
P1 / P2
P1 / P2
DC9VS / DC6VS / DX17VSS FIT. P1/P2 indoor–outdoor. DX16TC / DX13SA / DC5SE are 24V — different diagrams.
Written circuit description only — FieldBench does not redraw maker schematics. Example: R to W closes on a heat call; verify 24V at W1 before you change the IFC.
Open manufacturer PDFP1 / P2
Daikin One / ComfortNet / FIT communicating indoor.
Communicating indoor
P1/P2 to the outdoor. Not S1/S2/S3 Mitsubishi.
- P1ComfortNet / FITData
- P2ComfortNet / FITData
FIT outdoor
Same P1/P2. Polarity matters.
- P1DataData
- P2DataData
Outdoor line — inverter drive
208/230 into the drive. No contactor slam. DC bus can stay live after the disconnect.
- L1Line to the driveLine
- L2Line to the driveLine
- GNDEquipment groundLine
Landing
- DataIndoor P1outdoor P1 · P2P2
Data. Not 24 VAC Y.
- LineL1 / L2outdoor
208/230
Prove it
- Daikin One / ComfortNet sees the outdoor.
- P1/P2 landing and polarity. Never megger P1/P2.
Do not
- Do not assume Mitsubishi S1/S2/S3 pinout.
- Do not apply this to DX13SA / DC5SE / DX16TC.
P1/P2 is the published Daikin ComfortNet / FIT pair.