Heat pump defrost

Frost can be normal. A block of ice that never clears is a defrost, airflow, or charge problem.

Normal vs fault

  • Light even frost on a cold, damp day is expected. Ice bridging the whole coil with a running fan is not.
  • During defrost the outdoor fan should stop, the reversing valve should shift to cool, and the coil should steam.

Checks

  • Defrost sensor ohms and placement (OEM clip point, not a random return bend).
  • Reversing valve: pressure swap and suction temperature when it should be in defrost.
  • Outdoor fan relay on the board — a fan that stays on in defrost will not clear the coil.
  • Charge. A starved outdoor coil in heat ices fast and defrosts poorly.
  • Aux / emergency heat should stage if defrost is long — confirm W2 / E wiring.